Hertel in ophthalmology
WitrynaMethods: In a population-based epidemiologic study, Hertel exophthalmometry was performed on 1063 randomly selected normal subjects (stratified sampling) by an … WitrynaThis instrument is used for precise exophthalmos measurements (e.g. exophthalmic goiter). The basis of the measurement for exophthalmos determination using the Hertel version is the outer orbital rim (orbital wall) and the apex of the cornea. The integral refraction mirrors with millimeter scales for the left-hand and right-hand measuring …
Hertel in ophthalmology
Did you know?
Witryna3 wrz 2024 · Degree of proptosis was independently measured by one experienced clinical observer (ophthalmologist) who used the Hertel exophthalmometer (Oculus … WitrynaThe Hertel exophthalmometer quantifies the anterior protrusion of the eye by measuring the distance in millimeters from the lateral orbital rim to the front surface of the …
Witryna1 wrz 1985 · The Reliability of Hertel Exophthalmometry: Observer Variation between Physician and Lay Readers+,++ ... Reliability of ophthalmic diagnoses in an … Witryna19 gru 2016 · The Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as …
WitrynaPurpose: To assess the effect of simultaneous measurement of the two eyes in Hertel exophthalmometry (i.e., when both readings are taken sequentially, without removing the instrument from the orbital rims) and to find out whether simultaneous measurement would influence the final reading of each eye. Methods: In this prospective, … Witryna1 gru 2003 · Hertel exophthalmometry is a reliable method for measuring the ocular protrusion. However, as with most clinical measures, there is a negligible interobserver variation that seems to be...
Witryna1 wrz 1985 · The Reliability of Hertel Exophthalmometry: Observer Variation between Physician and Lay Readers+,++ ... Reliability of ophthalmic diagnoses in an epidemiologic survey. Am J Epidemiol, 118 (1983), pp. 265-279. CrossRef View Record in Scopus Google Scholar. 8. T Olsen, CB Nielsen, N Ehlers.
Witryna1 wrz 1999 · Editor,—The common method used in Hertel exophthalmometry involves aligning the corneal apex with the reference cone on the exophthalmometer and … brookshire\u0027s line avenue shreveport laWitryna15 godz. temu · Stefanie Hertel und ihre Tochter Johanna Mross sind seit jeher eng verbunden. Ähnlich wie die Mutter-Tochter-Beziehung im Musical „Mamma Mia!“ sind … care homes in chesham bucksWitrynaResidents participate in comprehensive ophthalmology and subspecialty clinics, including cornea, retina, glaucoma, and neuro-ophthalmology. Residents spend a … care homes in cheshunt hertsWitrynaHertel exophthalmometry: the most appropriate measuring technique. N. O'DONNELL, M. VIRDI, and E. KEMP. ... Full Text. The Full Text of this article is available as a PDF … brookshire\u0027s mabank pharmacyWitryna13 kwi 2024 · About 70% of breast cancer patients are oestrogen receptor-positive (ER +ve). Adjuvant endocrine therapy using tamoxifen (TAM) is an effective approach for preventing local recurrence and metastasis. However, around half of the patients will eventually develop resistance. Overexpression of BQ323636.1 (BQ) is one of the … care homes in chessingtonWitryna10 cze 2024 · Exophthalmometry 1. Exophthalmomet ry Raju Kaiti, M. Optom Consultant Optometrist 2. Introduction Orbital disorders can be associated with … brookshire\u0027s kings highway pharmacyWitryna1 paź 1999 · Currently, the main clinical methods for measuring exophthalmos can be classified as exophthalmometer and computed tomography (CT) methods. The most widely used method is the Hertel ... care homes in chobham